• Gasket Online Leak Sealing

    Gasket Online Leak Sealing

    Client:

    A major company in the Australian engineering industry.

    Location:

    Regional Queensland

    Related Services:

    Related Industries:

    Project Brief

    BLJ was tasked to rectify a gasket leak from flange joint flow element.


    Solution

    To manage and repair the leak, BLJ we manufactured a leak sealing clamp and mobilised 2 technicians on site.

    BLJ technicians were required to custom design and manufacture a mechanical retaining device (clamp) solution to meet clients specific application. They installed a 1-1/2” 600lb flange and injected compound to stop the leak and effect a seal. 

    Leak Sealing is a temporary fix to get the plant through to the next scheduled shutdown when the item is repaired or replaced to work within the clients timeframe and resources. Clamps are designed to meet ASME VIII or AS1210 design codes 

    Product: MP steam

    Design Temperature: 260 degrees Celcius

    Design Pressure: 540 PSI


    Results

    It was a clean leak seal with no downtime or disturbance – clients plant remained online during the repair process. 

    We look forward to working with you.

    For more information on our services, please fill out the form and one of our team members will be in touch.